Page 34 Duende Native User Guide
P
arallel
T
he parallel button changes the order in which the six central bell-shaped bands are processed. In normal (serial) mode, they
a
re processed one after the other. In parallel mode, once the signal has passed through the LF filter and shelf bands, it is split
o
ff and routed through each bell band simultaneously, before being combined again for the HF shelf and filter bands:
The parallel EQ is modelled on the old ‘Parallel Passive’ EQ units, and the different style of band interaction means that the
EQ performs quite differently. See the EQ History section on Page 41 for more information.
EQ PARAMETER VALUES
Band Gain Frequency Q
HP Filter n/a 20Hz – 1020Hz 0 – 48dB/oct in 6dB steps
Low Shelf ±20dB 20Hz – 1020Hz 0.3 – 10.3
Midband 1 ±20dB 20Hz – 20kHz 0.3 – 10.3
Midband 2 ±20dB 20Hz – 20kHz 0.3 – 10.3
Midband 3 ±20dB 20Hz – 20kHz 0.3 – 10.3
Midband 4 ±20dB 20Hz – 20kHz 0.3 – 10.3
Midband 5 ±20dB 20Hz – 20kHz 0.3 – 10.3
Midband 6 ±20dB 20Hz – 20kHz 0.3 – 10.3
High Shelf ±20dB 500Hz – 20kHz 0.3 – 10.3
LP Filter n/a 500Hz – 20kHz 0 – 48dB/oct in 6dB steps
Serial
Parallel
LF Filter
a
nd Shelf
EQ
HF Shelf
E
Q and
Filter
6 Bell Bands