Whentheradioadaptorbatteryischanged,theprogramrequirestobesentagainbyradio.This
applieswheretheradioadaptorisfittedonanoldTBOS™module.
6. Transmittingaprogramvialaradio
Thisoperationisperformedinthesamewayasforatransmissionviainfrared.Oncetheirrigation
programhasbeenchanged,itcanbetransmittedbyradiototheTBOS™controllerofyourchoice.
Select"Transmit"fromtheWelcomemenuandconfirmbypressingOK
Iftheprogramisincomplete,ascreenindicatesthemissingfields.
Completemissingdatauntilthetransmissionsuccess.
F. Sensor
1. OverallDescription
AyellowloopisavailableoneachTBOS/TBOSIIControlModuletoaccommodateadrycontact
sensor.
WARNING
:TBOSControlModules(oldmodels)canonlyaccepttheDrycontactSensor.Aswitch
stateofthesensoraffectsallthevalves.
TBOSIIControlModulesaccept2typ esofsensor:
Bydefault,Drycontactsensorsas:
o RainSensor(RainBirdRSDBex)
o TBOScontroll
ersavesstateswitch.
Variablepulserateflowmeters/sensors
o TBOSControllercountspulses(max10pulsespersecond)
o ThiskindofsensorispolarizedRefertopolarity(+/)gravedonTBOSIIControl
Modulefortheconnectionontheyellowloop.
o ThosesensorshavetobesetupfromIQSoftware.
Eachvalveoutputcanbeaffectedornotbyastateswitchofthesensorindependently
.
FlowmanagementisavailableonlywhenthecontrollersarecentralizedonIQV2Software.IQ2
withstandsupto4sensorsperTBOSNetwork.
Alarmsareautomaticallycommunicatedevery12hours.TBOSIIRadioAdaptorsisinchargeof
reportingtheinformationtotheIQTBOSMasterRadioModule. Thenth
eMasterRadiomodule