4- MOUNTING AND WIRING MODULE
The BL case must be installed indoor use only. It can be xed against a wall
with the screws supplied with the product.
Cabling of the transformer to the power supply:
- The BL case must be installed the nearest possible of the electric plug.
The power plug must be accessible at all me in order to unplug the device in
case of emergency.
- Make sure that the power plug on which the transformer is plugged in has
a overcurrent and short-circuit protecon breaker for 16A (20A for US).
Wiring of the 4 output lines:
- Each line must be protected by a circuit breaker which should be idened
and easily accessible.
- The 230V (120V in the U.S) cables which are used to power the 4 lines must
have either a double insulaon or a reinforced insulaon.
- Cables used for wiring must be of type H05VV-F or H03VV-F and
of secon 2x1,5mm².
Maximum electric charge :
For a 230V installaon : 4000W (16A*) total over all lines and up to only
3500W
on one single line.
For a 120V installaon : 2000W (16A*) total over all lines and up to only
1700W
on one single ligne. Use only power supply provided with product 120V 0.75A
*16A max for resisve load
1,7A max for inducve load
Max operang temperature : 45°C