4- MOUNTING AND WIRING MODULE
The BL case must be installed indoor use only. It can be xed against a wall
with the screws supplied with the product.
- The BL case must be installed the nearest possible of the electric plug.
The power plug must be accessible at all me in order to unplug the device
in case of emergency.
- Make sure that the power plug on which the transformer is plugged in has
a overcurrent and short-circuit protecon breaker for 16A (20A for US).
Use only power supply provided with product 24Vac 0.75A
Max operang temperature : 45°C
Then
Direcon of
installaon
112mm
Use Solenoid valves with 24Vac
75mm
P-18