User's Manual
This document is Solectek CONFIDENTIAL and may not be reproduced without written permission. V1.5
1. Introduction
For the Phase II release, the Configuration of the MRS boardset can be changed in three ways:
HTTP GUI, Telnet and Configuration File.
1. The GUI is functional, though per Solectek schedule, is not completely functional.
2. Telnet may be used to work with the commands listed in this document.
3. The Configuration File may be offloaded, modified and re-stored on the MRS.
2. Unit Power
The MRS boardset is intended to be powered via the 2pin, +48V connector on Minotaur. The Solectek
Base Station is to be powered via PoE, supplied by the included Power Supply/Injector and connected
into the RJ45 Minotaur connector
3. Unit Access
Both HTTP and Telnet access is password protected. Default access is as follows:
Login: Root
Password: Solectek
4. Unit Defaults
MRS Boardset Solectek Base Station
Network Mode Bridge Bridge
Ethernet IP Address 172.21.0.100/255.255.0.0 172.21.0.10/255.255.0.0
RF IP Address 192.168.1.x/255.255.255.0 192.168.1.x/255.255.255.0
RF Mode Client Access Point
SSID Koito_2 Koito_2
Encryption Open Open
RF Bandwidth 20 MHz 20 MHz
5. Telnet
Any Telnet client can be used to access the MRS and Base Station devices. Access is per
login/password above. Once logged in, configuration can be adjusted by two methods: (a)
direct commands, or by (b) modifying the configuration file.
5.1. Direct Commands
set_config
The set_config can be used to change (or add) a configuration variable. On in the Telnet
shell, the command may be invoked as: