14. Telnet
Using the radio’s IP address, the system can be managed using a Telnet
connection.
Access login and password are the same for a Telnet session as for the HTTP
GUI.
Sessions can be initiated from both the Ethernet and RF side of the Network,
and multiple sessions are permitted.
Note: the ‘savecfg’ command must be used to save Telnet configuration
changes to non-volatile memory.
See Appendix B for a complete Telnet command set, syntax and usage.
15. SNMP
The SkyWay management system includes ‘get’ support for SNMP v2c via
standard and private MIB tables.
Navigate to Management -> SNMP to access the SNMP Configuration screen:
SNMP Enable: For security purposes, the SNMP engine can be disabled, if not
used.
Community Names and Trap Manager IP Address fields should be entered
based on the configuration of your SNMP Manager software.
The private MIB (P/N 1539901) is available on Solectek’s Support website or
from Solectek Technical Support personnel.
For further information about SNMP management, the following documents
available on Solectek’s Support Website may be helpful:
SkyWay Excel SNMP Usage Guide (1553101)
SNMP Objects for Monitoring SkyWay Excel (1559201)
Additional Notes:
(a) SNMP community fields are case sensitive with no spaces allowed. Fields
must be between 1 and 64 characters in length.
(b) Legal characters are: all alphanumerics, plus the following symbols:
@ (at sign) - (dash) . (period) ‘ (tick) _ (underscore)