User's Guide
Table Of Contents
- SkyWay Wireless Bridge/Router User's Guide
- Table of Contents
- Chapter 1: Introducing Skyway
- Chapter 2: Getting to Know the SkyWay Bridge/Router
- Chapter 3: Preparing for Installation
- Chapter 4: Installing Skyway
- Chapter 5: Configuring and Managing SkyWay
- Configuring SkyWay
- Setting System Configuration Parameters
- Understanding RF-DLC
- Configuring the Ports
- Bridging
- IP Routing
- Internet Control Message Protocol
- SNMP
- Diagnostics
- File Transfer Utilities
- Security
- Chapter 6: Monitoring SkyWay
- Chapter 7: Troubleshooting Skyway
- Appendix A: Run-time Menu Tree
- Appendix B: BIOS Menu Tree Summary Table
- Appendix C: Interface Specifications and Pinouts
- Appendix D: Detailed Product Specifications
- Appendix E: Supported Protocols
- Appendix F: Error Codes
- Appendix G: SNMP Trap Messages
- Appendix H: Installation Recording Form
- Appendix I: Sources of SNMP Management Software
- Appendix J: Glossary and Basic Concepts
- Appendix K: Skyway Antennas
- Note:
- Note:
- Note:
- 7002301: 6 dBi Omni Directional Antenna
- 7002401: 11 dBi Omni Directional Antenna
- 7002501: 16 dBi Outdoor Flat Panel Directional Antenna
- 7002601: 17 dBi Outdoor Flat Panel Directional Antenna
- 7002701: 22 dBi Outdoor High gain Flat Panel Directional Antenna
- 7002801: 8 dBi Indoor/Outdoor Patch Antenna
- 7002901: 12 dBi 110 ˚ Outdoor Sectorial Antenna
- Index
Diagnostics
105
4.1 RF Base Radio Test
The following lists the field name, the MIB name, and the default setting:
Field Name MIB
Settings (default in
bold)
RF Port Number [swRFBaseTestIndex] 3
The RF port number is 3.
Te s t T i m e o u t [swRFBaseTestTO] 8
The timeout value in milliseconds. This is the amount of time the test will run before
terminating on its own.
Test to Run: [swRFBaseTestToRun] See the following table:
Select a test to run and press
.W to begin the test. There are five tests you can run
on the base port as described in the following table. To end the test, set Test to Run
t o Te r m i n a t e Te s t a n d p r e s s
.W.
Te s t To R u n
Parameters that
can be configured
Comments
Burst Frame Ping Pong
Mode
Test Timeout, Number
of Bursts, Maximum
Burst Size
The base station sends
the specified number of
bursts, and the sub sta-
tion returns the same
number.
4.1 RF Base Radio Test
** Note - diagnostic driver must be installed **
RF Port Number : 3
Test Timeout : 8 milliseconds
Test To Run : Terminate Test
Number of Frames or Bursts, 1 - 65535 or 0 for Continuous. :0
Frame Length or Maximum Burst Size, 3 - 3200 :1530
\ - return to menu . - commands TAB - next available field ENTER - edit