Technical Specifications
Mouli Engineering © 2014 SolarPod
◌
TM
Grid Tied www.mouliengg.com ; 612-424-5176; Manual version 16.0
U.S. Patent No. 8,716,889
The Line
diagram to the
left is when the
utility requires a
bidirectional
meter installed.
Typically this is
required by the
utility when the
utility gives
solar rebates and
does not wish to
install a
production
meter for the
renewable
energy credits.
Panel brand used is only for illustrative purposes for the line diagram.
Run #6 ground wire through each inverter and frame (lug nuts provided) and use a ground rod
appropriately distanced from the original. Ensure the ground wires are well connected in each of the
inverter.
Multiple SolarPod
◌TM
Grid Tied wiring: Four SolarPod
◌TM
Grid Tied can be wired in series to one
dedicated 20A two pole circuit breaker. Each SolarPod
◌TM
Grid Tied comes with male receptacle on one
end and an end terminator on the other end. Only a female receptacle can be placed instead of the end
terminator. Please see below diagram to understand the serial male/female receptacle connections.