Specications
See specications in the following tables for:
y IQ7+
y Enphase Q Cable
Enphase IQ7+
IQ7+ MICROINVERTER PARAMETERS
TOPIC UNIT MIN TYPICAL MAX
DC PARAMETERS
Peak Power Tracking Voltage V 27 36 45
Operating range V 16 62
Maximum DC input voltage V 62
Minimum / Maximum start voltage V 22 62
Maximum DC input short circuit current (module Isc) A 15
Overvoltage class DC port II
DC Port backfeed under single fault A 0
PV array conguration
1 x 1 ungrounded array; No additional DC side protection required;
AC side protection requires max 20 A per branch circuit
AC PARAMETERS
Maximum Continuous AC output Power (-40 to +65ºC) VA 280
Peak output power VA 290
Power factor (adjustable) 1/0.7 leading, 0.7 lagging
Nominal AC output voltage range
240 VAC (single phase)
208 VAC (single phase)
Vms
Vms
211
183
240 264
229
Maximum continuous output current
240 VAC (single phase)
208 VAC (single phase)
A
A
1.21
1.39
Nominal frequency Hz 60
Extended frequency range Hz 47 68
Maximum AC output over current protection device A 20
Maximum AC output fault current & duration Arms over 3 cycles 5.8
High AC Voltage trip limit accuracy % +_1.0
Low AC Voltage trip limit accuracy % +_1.0
Frequency trip limit accuracy % +_1.0
Trip time accuracy milliseconds +_33
Overvoltage class AC port III
AC port backfeed under single fault A 0