Installation manual
36
Safety, Installation, and Operations Manual
© Solaria Corporation All rights reserved. Contents subject to change without notice 8-26-19
Power Unlocked by Design
L. On the ground, use the Installer Toolkit mobile app to delete the old microinverter serial number from the Enphase
IQ Envoy database. In Installer Toolkit, once connected to the Envoy:
a. Tap Micros > Manage.
b. Tap the checkbox to the right of the microinverter serial number that you replaced.
c. Tap to delete the microinverter from the Envoy-S database.
M. Add the new microinverter serial number to the Envoy database by initiating a device scan using one of the
following methods:
a. Method 1: Initiate a scan using the Installer Toolkit mobile app
y In Installer Toolkit, once connected to the IQ Envoy, navigate to the Overview screen.
y From the Overview screen, tap Detected > Start Device Scan to start a new 30-minute device scan.
y If device scanning on the IQ Envoy is inhibited, the app displays Scan Inhibited. If you need to add more
microinverters to the system when device scanning is inhibited on the IQ Envoy, you must use the Installer
Toolkit scanning tool to provision them on the IQ Envoy, rather than using the IQ Envoy’s device scanning
function to discover them. If this is not possible and you need to enable device scanning on the IQ Envoy,
contact Enphase Customer Support at enphase.com/en-us/support/contact.
b. Method 2: Use an IQ Envoy
y Press the Device Scan button on the IQ Envoy. The IQ Envoy begins a 15-minute scan to identify all of the
microinverters deployed at the site. The Microinverter Communications LED ashes green during the scan.
N. Log in to Enlighten to use Enlighten’s Array Builder to add the newly detected microinverter to the virtual array.
O. Ship the old microinverter to Enphase using the supplied return-shipping label.
Microinverter Communications LED
Device Scan button