Installation manual

24
Safety, Installation, and Operations Manual
© Solaria Corporation All rights reserved. Contents subject to change without notice 8-26-19
Power Unlocked by Design
y Mounting Using Rail-less Racking Systems:
Typical rail-less racking system layout is shown in the diagram below.
Attachments are to be made on the long side of the module with maximum attachment span of 48 inches
and maximum cantilever of 17 inches.
Follow racking system manufacturer’s recommendations for coupling clamps at the module corners,
torques, and bonding methods.
For rail-less systems, maximum allowed loading is 2400Pa (front) and 2400Pa (rear).
Clamps should be clear of the microinverter by at least 1 ½”.
6.3 Module Direction and Tilt Angle
y Modules produce maximum energy when they are pointed directly to the Sun. Modules get maximum sunlight
throughout the year if they face South in Northern Hemisphere and they face North in Southern Hemisphere.
6.4 Module Orientation
y Modules can be mounted in either “portrait” or “landscapeorientation relative to the roof but the mounting
rails must always run perpendicular to the long side of the module so as to not interfere with the AC unit.