y Mounting Using Clamps:
When using clamps, place clamps within the allowable clamping areas identied in the table and
diagrams below. Follow clamp manufacturer’s recommended hardware and torque requirements for solar
installations. Various clamp systems specically designed for PV module mountings are available and
compatible with Solaria PowerXT
®
. In the absence of manufacturer’s recommendations for clamp size,
Solaria recommends minimum clamp size of 40mm (1.57”).
Maximum Allowed Loading:
355Wp 365Wp 365Wp
Clamping Area Clamp Area A Clamp Area A Clamp Area B
Front Load 5400Pa 5400Pa 2400Pa
Rear Load 3600Pa 3600Pa 2400Pa
Note, rails supporting the clamped connections should always run perpendicular to the length of the
module.
Rails and clamps should be clear of the microinverter by at least 1 ½” when following these guidelines.
Allowable rail locations, top view (left) and example of typical rail conguration, back view (right)