Mounting Requirements:
Modules can be secured with bolts or clamps.
y Mounting Using Bolts at Mounting Slot Locations:
Use the four 7.0mm [0.28in] x 10.0mm [0.39in] “MOUNTING SLOTS” shown on the diagram below and on
module drawing in section 8. Use M6 (1/4″-20) stainless steel bolts, with nuts, two washers, and a locking
washer, tightened to a minimum torque of 13.6-16.3 N-m (10-12 ft-lb).
When bolts are used for mounting, maximum allowed loading is 5400Pa (front) and 3600Pa (rear).
Note, rails supporting the bolted connections should run perpendicular to the length of the module so as to
not interfere with the AC unit (see diagram on next page)
3.7 in
2.0 in
1.7in
2.0 in
15.4 ± .2 in
14.6 ± .2 in
16.9 ± .2 in
16.1± .2 in
OPTION 1
POWERXT-355R-PDX-AC
MICROINVERTER
AND
CABLE BASE
POSITION
OPTION 2
POWERXT-365R-PDX-AC
MICROINVERTER
AND
CABLE BASE
POSITION