Step 5: Prepare the AC Modules
A. Before installing the AC module, the microinverters must be lifted from the shipping position. On the ground,
turn the AC Module so that the microinverter faces you. Using both hands, lift the microinverter up. You will hear
four clicks as the microinverter locks into the installation position. Ensure the four latches are locked, and the
microinverter is not tilted.
NOTE: If you need to move the module, you can return the microinverter to the shipping position using
the Enphase Disconnect Tool. Use the tool to depress the four locking mechanisms on each corner of the
microinverter to return it to the shipping position.
B. Position the AC Modules as planned on the rail.
The Microinverter is in the shipping position.
The Microinverter is lifted and ready for installation.
Make sure the microinverter is not tilted.
Use this end of the Disconnect Tool
to depress the locking mechanisms.