Installation manual

18
Safety, Installation, and Operations Manual
© Solaria Corporation All rights reserved. Contents subject to change without notice 8-26-19
Power Unlocked by Design
Step 3: Connect to a Junction Box
A. Connect the Enphase Q Cable into the junction box.
B. Refer to the wiring diagrams on page 44 for more information. Wire colors are listed in the following table.
WIRE COLORS
L1 – Black
L2 – Red
Step 4: Terminate the Unused End of the Cable
Place sealing caps on unused connectors and terminate the unused end of the Enphase Q Cable as follows.
A. Cover any unused connectors with Enphase Sealing Caps. Listen for a click as the connectors engage.
WARNING: Risk of electric shock. Risk of re. Install sealing caps on all unused AC connectors as these
connectors become live when the system is energized. Sealing caps are required for protection against
moisture ingress.
NOTE: If you need to remove a sealing cap, you must use the Enphase Disconnect Tool. See “Remove and
Replace a Microinverter” on page 35.
B. Remove 13 mm (½ inch) of the cable sheath from the conductors. Use the terminator loop to measure 13 mm.
C. Slide the hex nut onto the cable. There is a grommet inside of the hex nut that should remain in place.
Terminator Body 13mm