Step 3: Connect to a Junction Box
A. Connect the Enphase Q Cable into the junction box.
B. Refer to the wiring diagrams on page 44 for more information. Wire colors are listed in the following table.
WIRE COLORS
L1 – Black
L2 – Red
Step 4: Terminate the Unused End of the Cable
Place sealing caps on unused connectors and terminate the unused end of the Enphase Q Cable as follows.
A. Cover any unused connectors with Enphase Sealing Caps. Listen for a click as the connectors engage.
WARNING: Risk of electric shock. Risk of re. Install sealing caps on all unused AC connectors as these
connectors become live when the system is energized. Sealing caps are required for protection against
moisture ingress.
NOTE: If you need to remove a sealing cap, you must use the Enphase Disconnect Tool. See “Remove and
Replace a Microinverter” on page 35.
B. Remove 13 mm (½ inch) of the cable sheath from the conductors. Use the terminator loop to measure 13 mm.
C. Slide the hex nut onto the cable. There is a grommet inside of the hex nut that should remain in place.
Terminator Body 13mm