Product Specifications
StorEdge
TM
Single Phase Inverter
for North America
SE3800A-US
(1)
,
SE7600A-US
(1)
Single inverter for PV, grid-ed storage and backup power
Includes the hardware required to provide automac backup power to backed-up loads in case of grid interrupon
Includes all interfaces needed for baery connecon
UL1741 SA cered, for CPUC Rule 21 grid compliance
SE3800A-US SE7600A-US
OUTPUT - AC (LOADS/GRID)
Rated AC Power Output 3800 7600 VA
Max AC Power Output 4175 8350 VA
AC Output Voltage Min-Nom-Max (L-L)
(2)
211-240-264 Vac
AC Frequency Min-Nom-Max
(2)
59.3 - 60 - 60.5 Hz
Maximum Connuous Output Current @240V 16 32 A
GFDI 1 A
Ulity Monitoring, Islanding Protecon, Country Congurable
Thresholds
Yes
Charge Baery from AC (if Allowed) Yes
THD <3 %
Typical Nighme Power Consumpon <5 W
OUTPUT - AC (BACKUP POWER)
(3)
Rated AC Power Output 5000
(4)
VA
Max AC Power Output - Surge (for 10 seconds) 7000
(4)
VA
AC Output Voltage Min-Nom-Max (L-L) 211-240-264 Vac
AC Output Voltage Min-Nom-Max (L-N) 105-120 -132 Vac
AC Frequency Min-Nom-Max 55 - 60 - 65 Hz
Maximum Connuous Output Current @240V - Backup Mode 21 A
Max Connuous Output Current per Phase @120V 25 A
GFDI 1 A
AC Circuit Breaker Yes
THD <5 %
Automac switchover me <2 sec
INPUT - DC (PV and BATTERY)
Transformer-less, Ungrounded Yes
Max Input Voltage 500 Vdc
Nom DC Input Voltage 400 Vdc
Reverse-Polarity Protecon Yes
Ground-Fault Isolaton Detecon 600kΩ Sensitvity
Maximum Inverter Eciency 98 %
CEC Weighted Eciency 97. 5 %
INPUT - DC (PV)
Maximum DC Power (STC) 5100 10250 W
Max Input Current
(5)
13 23 Adc
2-pole Disconnecon Yes
INPUT - DC (BATTERY)
Supported Baery Types LG Chem RESU10H
Number of Baeries per Inverter 1 or 2
(6)
Connuous Power 5000 W
Peak Power 7000 W
Max Input Current 17.5 Adc
2-pole Disconnecon Yes
DC Fuses on Plus and Minus 25A (eld replaceable)
ADDITIONAL FEATURES
Supported Communicaon Interfaces RS485 for baery, RS485, Ethernet, Cellular, ZigBee (oponal)
Revenue Grade Data, ANSI C12.20 Oponal
(7)
Integrated AC, DC and Communicaon Connecon Unit Yes
AC Disconnect Yes
Manual Inverter Bypass Switch Yes
DC Voltage Rapid Shutdown (PV and Baery) Yes, according to NEC 2014 and 2017 690.12
(8)
Auto-transformer thermal protecon Yes
(1)
These specicaons apply to inverters with part numbers SExxxxA-USS2 and connecon unit model number BCU-1PH-USS
(2)
For other regional sengs please contact SolarEdge Support
(3)
Not designed for standalone applicaons and requires AC for commissioning
(4)
The rated AC power output is the minimum between the AC Power Output and the baery connuous peak power
(5)
A higher current source may be used; the inverter will limit its input current to the values stated
(6)
When connecng two LG Chem baeries, each baery must have a dierent part number; supporng SolarEdge rmware required
(7)
Revenue grade inverter P/N: SExxxxA-USS2xxxYx or SExxxxA-USS2xxxMx
(8)
In case the inverter is not located in an accessible locaon for emergency responders (according to NEC 2017), use inverters with P/N SExxxxA-USS2Rxxxx ; for more informaon refer to:
hps://www.solaredge.com/sites/default/les/storedge_backup_installaon_guide_NA.pdf