Figure 28: StorEdge Connection Unit DIPīswitches
Connecting Communication to the Meter
If a meter was installed, connect it to the StorEdge Connection Unit as described in the
following table. For detailed information refer to the installation guide supplied with
the meter.
Recommended cable type
(min-max AWG)
StorEdge Connection
Unit
Meter connection
RS485 24 AWG (16-24
AWG), shielded twisted
pair, 600V insulated
Ext. Devices 7-pin
terminal block: B, A, G
RS485 4-pin terminal block: B, A, G
Connect as illustrated below:
StorEdge Solution with Backup MAN-01-00262-1.5
66 īīConnecting Communication to the Meter