8. Placethenewinverteronthemountingbracket;insertthescrewssecuringtheinvertertothe
mountingbracket.
9. ScrewthetwoconduitnutsintheinvertersecuringtheSafetySwitchtotheinverter.
10. ConnecttheDCandACwirestotheinverter.
11. IfferritebeadswereremovedfromtheDCandACwires,placethemonthewiresandclosethem.
MakesuretheDClabeledferritebeadisplacedontheDCwiresandtheAClabeledferritebeadis
placedontheACwires.
12. ClosetheSafetySwitchcoverandtheinvertercover.
13. PerformthecommissioningstepsasdescribedinActivating,CommissioningandConfiguringtheSystem
UsingtheInverterSetApponpage41.
Replacing the Safety Switch
Removing the Safety Switch
1. TurnOFFtheinverterON/OFF/Pswitch,andwaituntilthegreenLEDisblinking,indicatingthatthe
DCvoltageissafe(<50V),orwaitfiveminutesbeforecontinuingtothenextstep.
2. TurnOFFtheSafetySwitchandtheACbreakerofthedistributionpanel.
3. Opentheinvertercover.
4. DisconnecttheDCandACwiresfromtheinverter.IfthereareferritebeadsontheDCandACwiresin
theinverter,openthemandsetaside.
5.
UnscrewthetwoconduitnutsintheinvertersecuringtheSafetySwitchtotheinverter,asshown
below:
Figure 44: Disconnecting the conduits
6. OpentheSafetySwitchcoveranddisconnecttheDCandACwires.Unscrewthetwoconduitnuts
securingtheSafetySwitchtotheexternalconduits.
7. IftheSafetySwitchbracketisscrewedtothewall,releaseit.
8. CarefullyremovetheSafetySwitchwithitsmountingbracketfromthewall.
Installing a New Safety Switch
1. OpentheconduitdrillguidesofthenewSafetySwitch(refertoOpeningConduitDrillGuidesonpage
27).
2. PositionthenewSafetySwitchbelowtheinverterandfromtheinsideoftheinvertergrabtheACand
DCwiresextendingfromtheswitchconduits.
Appendix D: Replacing and Adding System Components
-Three Phase System Installation Guide MAN-01-00527-1.1
69