Communication Connectors
Twocommunicationglandsareusedforconnectionofthevariouscommunicationoptions.Eachgland
hasthreeopenings.Thetablebelowdescribesthefunctionalityofeachopening.Unusedopeningsshould
remainsealed.
Gland# Opening Functionality Cable Size (diameter)
1 (PG16)
One small External antenna cable 2-4 mm
Two large
Ethernet connection (CAT5/6) or
Cellular
4.5-7 mm
2 (PG13.5) All three RS485 2.5-5 mm
Figure 27: Communication Glands
ThecommunicationboardhasastandardRJ45terminalblockforEthernetconnection,anda6-pin
terminalblockforRS485connection,asshownbelow:
Figure 28: Internal connectors
Chapter 6: Setting Up Communication
-Three Phase System Installation Guide MAN-01-00527-1.1