Install Manual

Table Of Contents
l NC:NotConnected.RefertoTroubleshootingCommunicationonpage62
l S_OK:Theconnectiontothemonitoringplatformissuccessful(shouldappearonlyiftheinverteris
connectedtotheserver)
l N/A:NotApplicable
l x of y:Numberofdevicesconnectedoutofalldevices
l
Temporarilydisplayed(witha clocksign):
o
Initializing communication
o
Connectingtoanetwork
o
ConnectingtoSolarEdgeservers
l
Error message(withthe sign).RefertoTroubleshootingCommunicationonpage62.
Inverter Energy Status
Displaysthetotalenergyproducedduringthelastday,month,yearandsinceinverterinstallation.
InverterEnergy
Today
45 kWh
This Month
1.14 MWh
This Year
13.68 MWh
Total: 41.03 MWh
l Today:sincemidnight
l This Month:since1stofthecurrentmonth
l This Year:sinceJanuary1st
l Total (Wh):Theinvertertotalenergy.Ifanexternalmeterisinstalled,thevaluedisplayedinthisline
dependsonthemetertypeconnectedtotheinverteranditslocation:
o
Ifabidirectionalmeterisconnectedattheconsumptionpoint,thisvalueistheconsumedenergy.
o
Ifthemeterisinstalledattheproductionpoint,thisvalueistheenergyproducedbythesite.
o
Ifthemeterisinstalledatthegridconnectionpoint,thisvalueistheenergyexportedtothegrid.
Meter Status
Meters
Export RS485-2 Modbus ID #2
Status: OK
l Type and function:Displaysthemeterfunctionality(Production,Export,Import,Export+Import)
l Status:DisplaysOKifthemeteriscommunicatingwiththeinverter
l <Error message>:Ifthereisametererror,itisdisplayedinthisline.
l Power:Dependingonthemetertypeconnectedtotheinverter,thislinedisplaystheexportedor
importedpower
-Three Phase System Installation Guide MAN-01-00527-1.1
48
Inverter Energy Status