- Disclaimers
- Support and Contact Information
- Revision History
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimisers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Activating, Commissioning and Configuring the System Using the Inverter SetApp
- Chapter 6: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Mechanical Specifications
- Appendix C: External Fan Maintenance and Replacement
- Appendix D: Replacing and Adding System Components
- Technical Specifications - Three Phase Inverters (North America)
3.
WhenPairing Completeisdisplayed,thesystemstartupprocessbegins:
SincetheinverterisON,thepoweroptimizersstartproducingpowerandtheinverterstarts
convertingAC.
WARNING!
When you turn ON the inverter ON/OFF/P switch, the DC cables carry a high voltage and the power
optimizers no longer output a safe 1V output.
AVERTISSEMENT!
Après avoir mis l'interrupteur ON/OFF/P de l'onduleur monophasé sur ON, les câbles DC portent
une haute tension et les optimiseurs de puissance ne génèrent plus la tension de sécurité de 1V.
WhentheinverterstartsconvertingpoweraftertheinitialconnectiontotheAC,theinverterenters
Wakeupmodeuntilitsworkingvoltageisreached.Thismodeisindicatedbytheflickeringgreen
inverterLED.
Whenworkingvoltageisreached,theinverterentersProductionmodeandproducespower.The
steadilylitgreeninverterLEDindicatesthismode.
4. TapOKtoreturntothemainmenu.
Communication
Communicationsettingscanbeconfiguredonlyaftercommunicationconnectionsarecomplete.Refer
toSettingUpCommunicationonpage51.
1.
SelecttheCommunication menutodefineandconfigurethefollowing:
l Thecommunicationoptionusedbytheinvertertocommunicatewiththemonitoringplatform
l ThecommunicationoptionusedtocommunicatebetweenmultipleSolarEdgedevicesorother
externalnon-SolarEdgedevices,suchaselectricitymetersorloggers.
2.
TaptheServer redarrowtosetthecommunicationmethodtobeusedforcommunicationbetween
devicesandtheSolarEdgemonitoringplatform.ThedefaultisLAN.
NOTE
The Server menu shows only the communication options installed in the inverter.
Fordetailedinformationaboutalltheconfigurationoptions,refertotheCommunication
OptionsApplicationNote,availableontheSolarEdgewebsiteat
https://www.solaredge.com/sites/default/files/solaredge-communication_options_
application_note_v2_250_and_above.pdf.
Power Control
PowercontroloptionsaredetailedinthePowerControlApplicationNote,availableonthe
SolarEdgewebsiteat.
TheGridControloptionmaybedisabled.Enablingitopensadditionaloptionsinthe
menu.
TheEnergyManageroptionisusedforsettingpowerexportlimitation,asdescribedin
theExportLimitationApplicationNote,availableontheSolarEdgewebsiteat
https://www.solaredge.com/sites/default/files/export_limitation_application_note_
NA.pdf.
Chapter 5: Activating, Commissioning and Configuring the System Using the Inverter
-Three Phase System Installation Guide MAN-01-00527-1.1
43