Indication
ON/
OFF/ P
switch
position
LED color
Comment
Red Green Blue
Percentage of AC Production:
> 0 - 33 %
ON (1)
OFF OFF OFF
This indicates
power production
as percentage of
rated peak AC
output power
Percentage of AC Production:
0 - 33 %
OFF ON OFF
Percentage of AC Production:
33 - 66 %
OFF OFF ON
Percentage of AC Production:
66 - 100 %
OFF ON ON
l DC Safety Unit,including:
o
ON/OFF switch:connectsanddisconnectstheDCpowerofthesystem
o
AC conduit entries forconnectiontothegrid
o
DC AC conduit entries forconnectionofthePVinstallation
Figure 12: DC Safety Unit
NOTE
When the Safety Switch is OFF (for example during maintenance) it may be locked to prevent a safety
hazard:
1. Move the switch to the Lock position.
2. Insert the lock through the knob opening and lock.
-Three Phase System Installation Guide MAN-01-00527-1.1
26
Inverter Interfaces