Install Manual
Table Of Contents
- Disclaimers
- Support and Contact Information
- Revision History
- HANDLING AND SAFETY INSTRUCTIONS
- IMPORTANT SAFETY INSTRUCTIONS
- Chapter 1: Introducing the SolarEdge Power Harvesting System
- Chapter 2: Installing the Power Optimisers
- Chapter 3: Installing the Inverter
- Chapter 4: Connecting the AC and the Strings to the Safety Switch
- Chapter 5: Activating, Commissioning and Configuring the System Using the Inverter SetApp
- Chapter 6: Setting Up Communication
- Appendix A: Errors and Troubleshooting
- Appendix B: Mechanical Specifications
- Appendix C: External Fan Maintenance and Replacement
- Appendix D: Replacing and Adding System Components
- Technical Specifications - Three Phase Inverters (North America)
l ON/OFF/P Switch:
Figure 10: ON/OFF/P switch
o
ON (1)-TurningthisswitchON(afteroptimizerpairing)startstheoperationofthepower
optimizers,enablespowerproductionandallowstheinvertertobeginexportingpowertothe
utilitygrid.
o
OFF (0)-TurningthisswitchOFFreducesthepoweroptimizervoltagetoalowsafetyvoltageand
inhibitsexportationofpower.WhenthisswitchisOFF,thecontrolcircuitryremainspoweredup.
o
P-MovingandreleasingtheswitchallowsviewingsysteminformationviatheLEDsandonthe
SolarEdgeSetAppmobileapplicationscreenandperformingthefollowingfunctions:
P Position
duration
Function Comments
Switch moved to P for
less than 5
seconds, then
released.
o
Displays (via LEDs) production
information for 5 seconds, or error
type indications (if exist) for 5
seconds.
o
Activates the Wi-Fi access point
for connecting to the SetApp
While the switch is in P, all LEDs are
ON.
When the switch is released all LEDs
turn OFF for 0.5 sec and then display
the production or error indication.
Switch moved to P for
more than 5
seconds, then
released.
Starts pairing
Pairing is indicated by all 3 LEDs
blinking simultaneously.
LEDs
l LEDs:threeLEDsindicate,bycolorandstate(on/off/blinking
1
/
flickering
2
/alternating
3
),differentsysteminformation,suchaserrorsor
performanceindications.Formoreinformation,referto
https://www.solaredge.com/leds.
ThemainLEDindicationsare:
l BlueON-theinverteriscommunicatingwiththemonitoringplatform
l GreenON-thesystemisproducing
l Greenblinking-ACisconnectedbutthesystemisnotproducing
l RedON-systemerror
1
Blinking = Turns ON and OFF for the same duration
2
Flickering = Turns ON for 100 mS and turns OFF for 5 seconds
3
Alternating = alternate LED flashes
-Three Phase System Installation Guide MAN-01-00527-1.1
24
Inverter Interfaces