Install Manual

Table Of Contents
l ON/OFF/P Switch:
Figure 10: ON/OFF/P switch
o
ON (1)-TurningthisswitchON(afteroptimizerpairing)startstheoperationofthepower
optimizers,enablespowerproductionandallowstheinvertertobeginexportingpowertothe
utilitygrid.
o
OFF (0)-TurningthisswitchOFFreducesthepoweroptimizervoltagetoalowsafetyvoltageand
inhibitsexportationofpower.WhenthisswitchisOFF,thecontrolcircuitryremainspoweredup.
o
P-MovingandreleasingtheswitchallowsviewingsysteminformationviatheLEDsandonthe
SolarEdgeSetAppmobileapplicationscreenandperformingthefollowingfunctions:
P Position
duration
Function Comments
Switch moved to P for
less than 5
seconds, then
released.
o
Displays (via LEDs) production
information for 5 seconds, or error
type indications (if exist) for 5
seconds.
o
Activates the Wi-Fi access point
for connecting to the SetApp
While the switch is in P, all LEDs are
ON.
When the switch is released all LEDs
turn OFF for 0.5 sec and then display
the production or error indication.
Switch moved to P for
more than 5
seconds, then
released.
Starts pairing
Pairing is indicated by all 3 LEDs
blinking simultaneously.
LEDs
l LEDs:threeLEDsindicate,bycolorandstate(on/off/blinking
1
/
flickering
2
/alternating
3
),differentsysteminformation,suchaserrorsor
performanceindications.Formoreinformation,referto
https://www.solaredge.com/leds.
ThemainLEDindicationsare:
l BlueON-theinverteriscommunicatingwiththemonitoringplatform
l GreenON-thesystemisproducing
l Greenblinking-ACisconnectedbutthesystemisnotproducing
l RedON-systemerror
1
Blinking = Turns ON and OFF for the same duration
2
Flickering = Turns ON for 100 mS and turns OFF for 5 seconds
3
Alternating = alternate LED flashes
-Three Phase System Installation Guide MAN-01-00527-1.1
24
Inverter Interfaces