Installation Guide
Figure 33: Inverter fuse
6.
Turn ON:
The inverter ON/OFF switch
The Connection Unit
7. Verify proper system operation.
Replacing an Inverter
1. Turn OFF the inverter ON/OFF switch, and wait until the LCD indicates that the DC
voltage is safe (<50V), or wait five minutes before continuing to the next step.
WARNING!
If you cannot see the inverter panel, or if a malfunction is indicated on the
LCD panel, wait five minutes for the input capacitors of the inverter to
discharge.
AVERTISSEMENT!
Si vous ne pouvez pas voir l'écran de l'onduleur ou si un dysfonctionnement
est indiqué sur l'écran LCD, attendez cinq minutes pour que les
condensateurs d'entrée de l'onduleur soient déchargés.
2. Turn OFF the Connection Unit.
3. Disconnect the AC to the inverter by turning OFF the ACcircuit breaker of the
distribution panel.
4. Open the Connection Unit cover: Release the four Allen screws and remove the
cover.
Appendix C: Replacing and Adding System Components 95
EV Charging Single Phase Inverter Guide MAN-01-00404-1.2