Installation Guide
EV Charger-related Troubleshooting
For the following system errors, when an error occurs, the red LEDlights ON and the
buzzer beeps 10 times.
The error message is displayed on the SolarEdge mobile app screen and on the
LCDscreen.
If the error persists- contact SolarEdge Support.
Error code Displayed Error message Description and Troubleshooting
3x85 EVSEComm. Error
An internal communication error.
When this error occurs, the red
LEDis not lit, the buzzer does not
beep and charging is not affected.
Check that the internal connections
on the communication board are
properly done.
1Cx1; 1Cx8
Over Current
Disconnect from EV
EVCharger AC overcurrent.
Disconnect the EVCharger cable
from the vehicle and reconnect.
1Cx2; 1xC9
Over Voltage
Disconnect from EV
EVCharger ACvoltage too high.
Disconnect the EVCharger cable
from the vehicle and reconnect.
1Cx3
Ground Fault (RCD)
Press Charge Now
EVCharger ground fault detected.
Press the Charge Now button or tap
Charge Now in the EVCharger tab
of the Monitoring App.
1Cx4; 1Cx5;
1CxA/B/D/E;
1Cx10 -1Cx13
Internal Error.
Disconnect from EV
Internal error.
Disconnect the EVCharger cable
from the vehicle.
Turn the inverter ACcircuit
breaker OFF and ON.
Reconnect the EVCharger Cable
to the vehicle
Appendix A: Errors and Troubleshooting 89
EV Charging Single Phase Inverter Guide MAN-01-00404-1.2