Installation Guide
S i t e L i m i t : 7 . 0 k W
S i t e P r o d : 1 0 . 0 k W
S i t e E x p o r t : 4 . 0 k W
S e l f - c o n s u m e : 6 . 0 k W
Site Limit: The limit that was defined for the site
Site Prod: The power produced by the site
Site Export: The power that is fed into the grid
Self-consume: The PVpower consumed by the site
For more information, refer to the
Export Limitation Application Note
,
available on the SolarEdge website at
https://www.solaredge.com/sites/default/files/export_limitation_application_
note_NA.pdf.
Power Control Status
This screen is displayed only when Power Control is enabled (available from
communication board (CPU) firmware version 2.7xx/3.7xx and later).
P W R C T R L : R E M O T E
P W R L i m i t : 1 0 . 0 4 k W
C o s P h i : 0 . 9
P o w e r P r o d : 7 0 0 0 W
PWR CTRL: The power control status:
REMOTE - Communication with the RRCR or smart energy manager is
confirmed/validated.
LOCAL - The power is controlled locally (e.g. by a fixed limit), or this
inverter limits the PV power production to its relative portion of the
feed-in power limit, as a result of disconnected communication with the
smart energy manager. If this status appears, check the communication
to the smart energy manager or the communication to the meter.
Chapter 7: Configuring the Inverter 67
EV Charging Single Phase Inverter Guide MAN-01-00404-1.2