Installation Guide
Status: Displays OK if the inverter established successful connection and
communication with the specified server port/ (LAN, RS485 or ZigBee Plug-in).
xxxxxxxx: Eight-bit Ethernet communication connection status: A string of 1s
and 0s is displayed. 1 indicates OK, 0 indicates an error. For a list of the possible
errors and how to troubleshoot them, refer to
Errors and Troubleshooting
on
page 81.
Error message, according to failure. Refer to
Error Codes
on page 83.
IP Status
This screen describes the Ethernet configuration: IP, Mask, Gateway and MAC address
(Media Access Control) of the Inverter.
I P 1 9 2 . 1 6 8 . 2 . 1 1 9
M S K 2 5 5 . 2 5 5 . 2 5 5 . 0
G W 1 9 2 . 1 6 8 . 2 . 1
M A C 0 - 2 7 - 0 2 - 0 0 - 3 9 - 3 6
ZigBee Status
This screen describes the ZigBee configuration:
P A N : X X X X X
C H : X X / X X X X R S S I : < L >
M I D : X X X X X X
RSSI: The receive signal strength indication of the closest ZigBee in the system.
L = low, M = medium, H = high and (-) = no signal.
PAN ID: The ZigBee transceiver PAN ID (Personal Area Network Identification),
the IDuniquely represents a device in a Zigbee network.
Ch.: The ZigBee transceiver channel
ID: The ZigBee transceiver ID
MID: The Master ID of the coordinator (master) ZigBee Plug-in. This field is
shown only in devices with router (slave) ZigBee cards, and after a successful
ZigBee association. If a ZigBee Plug-in is not connected, a No ZigBee message
is displayed instead of the MID field.
Cellular Status
If a cellular (CDMA)Plug-in is connected, this screen replaces the Server status screen:
EV Charging Single Phase Inverter Guide MAN-01-00404-1.2
64 Status Screens - Operational Mode