Installation Guide
M o d u l e : 1 0 2 8 8 0 6 3 1 B
E n e r g y [ W h ] : 5 6 . 7
V d c _ O [ V ] : 4 0 . 0
V d c _ I [ V ] : 3 8 . 3
I _ i n [ A ] : 7 . 8
T e m p [ C ] : 2 8 . 0
Module: Power optimizer serial number
Energy: power optimizer energy
Vdc_O: Power optimizer output voltage
Vdc_I: Power optimizer input voltage (module voltage)
I_in: Power optimizer input current
Temp: Power optimizer temperature
ID Status
This screen displays the inverter software version and the country to which the inverter
is configured.
D S P 1 / 2 : 1 . 0 2 1 0 / 1 . 0 0 3 4
ID: The inverter ID.
DSP 1/2: The DSP digital control board firmware version
CPU: The communication board firmware version
Country: the current country setting
Server Communication Status
S e r v e r : L A N < S _ O K >
S t a t u s : < O K >
x x x x x x x x
< E R R O R M E S S A G E >
NOTE
If the connection method is CDMA (referred to as "Cellular" in the status
screens)or GSM, the server screen is replaced with the Cellular or GSM status
screens (see
Cellular Status
on page 64 and
GSMStatus
on page 65).
Server: The method of connection to the SolarEdge monitoring platform.
S_OK: The connection to the SolarEdge monitoring platform is successful
(should appear only if the is connected to the server).
Chapter 7: Configuring the Inverter 63
EV Charging Single Phase Inverter Guide MAN-01-00404-1.2