Installation Guide

Inverter Configuration Setup Mode
After inverter installation, an installer may perform basic system configuration.
Configuration is done when the inverter is in Setup mode.
To enter Setup mode:
1.
Turn the inverter ON/OFF switch to OFF (AC remains ON).
WARNING!
If the inverter was operating properly (power was produced by the power
optimizers), the following message is displayed.
D C V O L T A G E N O T S A F E
D O N O T D I S C O N N E C T
V D C : 7 2 . 0
This message is displayed until the DC voltage is safe (50V). Do not open
the cover until the voltage is safe or until at least five minutes have
passed.
AVERTISSEMENT!
La tension de sécurité par défault est de 50V.
Ne pas ouvrir le couvercle ou les connecteurs DC jusqu'à ce que la
tension soit affichée comme sécurisé ou jusqu'à ce que cinq minutes au
moins se soient écoulées.
2. Press the OK button for at least 5 seconds. The following message is displayed:
P l e a s e e n t e r
P a s s w o r d
* * * * * * * *
3. Press the Up, Down and OK buttons (Up=1, Down=2, OK=3) for entering the Setup
mode password: pqOK pqOK pq (12312312).
C o u n t r y < U S A + >
L a n g u a g e < E n g >
C o m m u n i c a t i o n
P o w e r C o n t r o l
D i s p l a y
M a i n t e n a n c e
I n f o r m a t i o n
The inverter is now in Setup mode and all its LEDs are lit. The inverter automatically exits
Setup mode if no buttons are pressed for more than 2 minutes.
EV Charging Single Phase Inverter Guide MAN-01-00404-1.2
52 Inverter Configuration Setup Mode