Installation Guide
Connecting the AC Grid to the Connection Unit
1. Strip 5/16'' (8mm) of the AC wire insulation.
2. Insert the AC conduit into the AC-side drill guide that was opened.
NOTE
Connect the equipment grounding before connecting the AC wires to the AC
terminal block.
Veillez à relier le conducteur de PE (la terre) avant de connecter les fils CA au
bornier CA.
3. Connect the wires to the appropriate terminal blocks according to the labels on the
terminal blocks (N, , L1 and L2).
4.
Use a standard flat-blade screwdriver to connect the wires to the spring-clamp
terminals. The screwdriver blade should fit freely in the terminal opening. Too large
a blade can crack the plastic housing.
a. Insert the screwdriver and press the release mechanism and open the clamp.
b.
Insert the wire into the round opening and remove the screwdriver – the wire is
automatically clamped.
Figure 20: AC Connection
EV Charging Single Phase Inverter Guide MAN-01-00404-1.2
38 Connecting the AC Grid to the Connection Unit