Installation Guide
NOTE
When the Safety Switch is OFF (for example during maintenance) it
may be locked to prevent safety hazard:
1. Move the safety switch to the Lock position.
2. Insert the lock through the knob opening and lock.
EV Charger cable connector: Used for connecting the EVcharger cable to the
inverter
EVCharger pushbutton:Pressing the button on the Safety Switch has the
following functionality:
For a system with scheduled charging: Start charging immediately (not
during charging scheduled times). For setting a charging schedule, refer
to the EV Charger Cable Installation Guide (supplied with the EV Charger
Cable).
In case of an error ,the system re-tests after 15 minutes. Pressing the
pushbutton performs the re-test immediately.
EV Charger LED indicator: Three LEDs indicate the EV Charger statuses.
Figure 12: LEDs
The following table lists the LED indications when the EV Charger Cable is
connected to the inverter and activated (refer to the EV Charger Cable
Installation Guide supplied with the EV Charger Cable):
Color Description
All LEDs OFF - No AC power available
Red ON - Error
Chapter 4: Installing the Inverter 31
EV Charging Single Phase Inverter Guide MAN-01-00404-1.2