Installation Guide
EV Charger and EV Charger Cable Specifications
OUTPUT — AC
Charging Level
AC Level 2
Connection to the SolarEdge monitoring
platform is required for first EV charging
Rated AC Power Output (Grid &
PV)
9600 W
Nominal AC Output Voltage 240 Vac
Nominal AC Frequency 60 Hz
Maximum Continuous Output
Current @240V
(Grid & PV)
40 Aac
Ground Fault Detection
Threshold
5 mA
ADDITIONAL FEATURES
EV Charger Status LEDs, Fault
Indicator
Yes
EV Charger Unplugging
Detection
Yes, current termination according to SAE
J1772
EV Charger Ground Connection
Monitoring
Yes, continuous
EV Charger Configuration
Via the monitoring app; Ethernet or ZigBee
connection is required
(1)
STANDARD COMPLIANCE
Safety - EVCharger
UL2594, UL2231-1, UL2231-2, NEC Article 625
compliant
EVCharger SAE J1772-2009
INSTALLATION SPECIFICATIONS
EV Charger Connector SAE J1772-2009
EV Charger Cable Length
(2)
25 / 7.6 (15 / 4.6 option) ft/ m
EV Charger Cable Weight 12.5 / 5.7 (7.7 / 3.5 for 15ft /4.6 m option) lb / kg
EV Charger and Cable Operating
Temperature Range
-22 to +122 / -30 to +50 °F/ °C
Protection Rating (connected to
EV or with dust cap)
NEMA 3R
(1)
Cellular connection may be used; requires a SIM card with a 1GB data plan that should be purchased from a cellular
provider.
(2)
EV Charger cable ordered separately.
EV Charging Single Phase Inverter Guide MAN-01-00404-1.2
104 EV Charger and EV Charger Cable Specifications