Single Phase Inverters for North America
SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US
SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US
OUTPUT
RatedACPowerOutput 3000 3800 5000 6000 7600 VA
Max.ACPowerOutput 3000 3800 5000 6000 7600 VA
ACOutputVoltageMin.-Nom.-Max.(183-208-229) - -
3
- - Vac
ACOutputVoltageMin.-Nom.-Max.(211-240-264)
3 3 3 3 3
Vac
ACFrequency(Nominal) 59.3-60-60.5
(1)
Hz
MaximumConnuousOutputCurrent208V - - 24 - - A
MaximumConnuousOutputCurrent240V 12.5 16 21 25 32 A
GFDIThreshold 1 A
UlityMonitoring,IslandingProtecon,
C o u n t r y C o n g u r a b l e T h r e s h o l d s 
Yes
INPUT
MaximumDCPower 4650 5900 7750 9300 11800 W
Transformer-less,Ungrounded Yes
MaximumInputVoltage 480 Vdc
NominalDCInputVoltage 380
400
Vdc
MaximumInputCurrent208V
(2)
- - 13.5 - - Adc
MaximumInputCurrent240V
(2)
8.5 10.5 13.5 16.5 20 Adc
Max.InputShortCircuitCurrent 45 Adc
Reverse-PolarityProtecon Yes
Ground-FaultIsolaonDetecon 600k Sensivity
MaximumInverterEciency 99 99.2 %
CECWeightedEciency 99 %
NighmePowerConsumpon <2.5 W
ADDITIONALFEATURES
SupportedCommunicaonInterfaces RS485,Ethernet,ZigBee(oponal),Cellular(oponal)
RevenueGradeData,ANSIC12.20 Oponal
(3)
RapidShutdown-NEC2014and2017690.12 AutomacRapidShutdownuponACGridDisconnect
STANDARDCOMPLIANCE
Safety UL1741,UL1741SA,UL1699B,CSAC22.2,CanadianAFCIaccordingtoT.I.L.M-07
GridConneconStandards IEEE1547,Rule21,Rule14(HI)
Emissions FCCPart15ClassB
INSTALLATIONSPECIFICATIONS
ACOutputConduitSize/AWGRange 0.75-1”Conduit/14-6AWG
DCInputConduitSize/#ofStrings/AWGRange 0.75-1”Conduit/1-2strings/14-6AWG
DimensionswithSafetySwitch(HxWxD) 17.7x14.6x6.8/450x370x174 in/mm
WeightwithSafetySwitch 22/10 25.1/11.4 26.2/11.9 lb/kg
Noise <25 <50 dBA
Cooling NaturalConvecon
Natural
conveconand
internalfan
(user
replaceable)
OperangTemperatureRange -13to+140/-25to+60
(4)
(-40˚F/-40˚Copon)
(5)
˚F/˚C
ProteconRang NEMA3R(InverterwithSafetySwitch)
(1)
ForotherregionalsengspleasecontactSolarEdgesupport
(2)
Ahighercurrentsourcemaybeused;theinverterwilllimititsinputcurrenttothevaluesstated
(3)
RevenuegradeinverterP/N:SExxxxH-US000NNC2
(4)
Powerde-rangfrom50˚C
(5)
-40versionP/N:SExxxxH-US000NNU4