StorEdge Inverter Datasheet
SolarEdge Meter and Current Transformers
SE-WNC-3D-240-MB / SE-ACT-0750-200 / SE-ACT-1250-400
ELECTRICAL SERVICE
Operang Voltage Range - Line to Line 211-264 Vac
AC Frequency 60 Hz
Grids Supported - Split Phase * L1 / L2 / N / PE
Power Consumpon (typ.) 1.8 W
Supported Communicaon Interfaces RS485
Response me ≤1sec sec
1% - 100% of Rated CT Current ±1.5 %
Safety UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04
Emissions FCC part15 class B
Dimensions (HxWxD) 3.35 x 6.02 x 1.50 / 85 x 153 × 38 in / mm
Weight 0.7 / 310 lb / gm
Enclosure type High impact, ABS and/or ABS/PC plasc UL 94V-0, IEC FV-0
Operang Temperature Range -22 to 131 / -30 to 55 F / °C
Relave Humidity (noncondensing) 5 - 90 %
Protecon Rang Indoor (Outdoor when installed in an IP66 / NEME3R/4 enclosure)
Mounng Type DIN Rail / Wall mount
* PE (Protecve Earth) connecon is not required for meter operaon
MODEL
RATED
SE-ACT-0750-200 200A 0.78 x 0.78 in; 2.40 x 2.38 in / 20 x 20 mm ; 61 x 60.4 mm
SE-ACT-1250-400 400A 1.26 x 1.83 in; 3.30 x 4.50 in / 32 x 46.5 mm; 83.4 x 114.0 mm
* For other rangs contact SolarEdge