Fuse Replacement
ReplacementkitsareavailablefromSolarEdgeoryoucanuseotherfuseswithidenticalratings.
1. TurnOFFtheinverterON/OFFswitch,andwaituntiltheLCDindicatesthattheDCvoltageissafe
(<50V),orwaitfiveminutesbeforecontinuingtothenextstep.
WARNING!
If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five
minutes for the input capacitors of the inverter to discharge.
Si vous ne pouvez pas voir l'écran de l'onduleur ou si un dysfonctionnement est indiqué sur
l'écran LCD, attendez cinq minutes pour que les condensateurs d'entrée de l'onduleur soient
déchargés.
2. TurnOFFtheStorEdgeConnectionUnitandtheACswitchofthedistributionpanel.
3. OpenandremovetheStorEdgeConnectionUnitcover.
4. Openandremovetheinternaltransparentcover.
5. RemovethefaultyfusefromtheupperboardoftheStorEdgeConnectionUnitandreplacewitha
newfuse.
6. ClosetheStorEdgeConnectionUnitcovers.
StorEdge Connection Unit Replacement
Removing the Existing StorEdge Connection Unit
1. TurnOFFtheinverterON/OFFswitch,andwaituntiltheLCDindicatesthattheDCvoltageissafe
(<50V),orwaitfiveminutesbeforecontinuingtothenextstep.
WARNING!
If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five
minutes for the input capacitors of the inverter to discharge.
Si vous ne pouvez pas voir l'écran de l'onduleur ou si un dysfonctionnement est indiqué sur
l'écran LCD, attendez cinq minutes pour que les condensateurs d'entrée de l'onduleur soient
déchargés.
2. TurnOFFtheStorEdgeConnectionUnitandtheACswitchofthedistributionpanel.
3. Opentheinvertercover.
4. DisconnecttheDCandACwiresfromtheinverter.OpentheDCandACwiresferritebeadsandset
themaside.
5. ForRGMinverter-DisconnecttheRS485connectorfromtheinvertercommunicationboard.
6. DisconnectthecableconnectingtheinverterdigitalboardtotheStorEdgeConnectionUnit.
7. UnscrewthetwoconduitnutsintheinvertersecuringtheStorEdgeConnectionUnittotheinverter.
8.
OpentheStorEdgeConnectionUnitcoveranddisconnect:
l PVDCwires
l Batterywires
l Auto-transformerwires,ifconnected
l Backed-uploadspanelwires,ifconnected
l Externalmeter,ifconnected