Step 3: Verifying Proper Operation
Afterthewake-uptimeisover,astatusscreensimilartothefollowingappearsontheinverterLCDpanel:
V a c [ V ] V d c [ V ] P a c [ W ]
2 4 0 . 7 3 7 1 . 9 2 3 4 9 . 3
P _ O K : X X X / Y Y Y < S _ O K >
. . . . . . . . . . . . . . . . . O N
1. Verifythefollowing:
l ThegreeninverterLEDissteadilylit.
l TheON/OFFindicatorontheLCDpanelreadsON.
l P_OK: XXX/YYY:Thereisaconnectiontothepoweroptimizersandatleastonepoweroptimizeris
sendingmonitoringdata.Optimizerssendtelemetriesinafrequencyofupto10minutes.Initiallyafter
pairing,bothXXXandYYYvaluesshow000andthevaluesincreaseaspairedpoweroptimizersare
reported.
NOTE
It may take up to 20 minutes for all power optimizers to transmit their telemetries and to be counted
on the LCD screen.
l S_OK appears,iftheinverterisconnectedtotheSolarEdgemonitoringportal.
l Vac [V]specifiesthemeasuredgridACoutputvoltage.
l Vdc [v] :SpecifiestheDCinputvoltage,whichshouldequalthesumoftheoutputvoltagesofall
modules(andshouldbewithintheoperatingrangeoftheinverter).
l Pac [W]specifiesthetotalACoutputpowerproduced.
2. Takenoteoftheserial#ontheinverterlabelusingthedetachable2Dbarcodestickeroneachdevice.
ThisinformationisusedintheSolarEdgemonitoringportaltoidentifythisinverterandisneededto
openanewsiteinthemonitoringportal.
YourSolarEdgepowerharvestingsystemisnowoperational.
Step 4: Reporting and Monitoring Installation Data
NOTE
This step requires connecting one of the communication options. Refer to Setting Up
Communication to the Monitoring Portal on page 71.
The SolarEdge Monitoring System
TheSolarEdgemonitoringportalenablesaccessingSolarEdgesiteinformation,includingup-to-date
informationviewedinaphysicalorlogicalview.Themonitoringportalisdescribedindetailinthe
SolarEdgeMonitoringPortalUserGuide,availableontheSolarEdgewebsiteat
http://www.solaredge.us/files/pdfs/solaredge-monitoring-portal-user-guide.pdf.TheSolarEdge
monitoringportalcandisplaylogicalandphysicallayoutsoftheinstalledsystem,asfollows:
l Logical Layout:Showsaschematiclogicallayoutofthecomponentsinthesystem,suchas:inverters,
stringsandmodules,aswellastheirelectricalconnectivity.Thisviewenablesyoutoseewhich
modulesareconnectedineachstring,whichstringsareconnectedtoeachinverter,andsoon.
l Physical Layout:Showsaschematicphysicallayoutofthecomponentsinthesystem,suchas:
inverters,stringsandmodules,aswellastheirelectricalconnectivity.Thisviewenablesabirdseye
viewoftheactuallocationofasystemcomponent.
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0
60
Step 3: Verifying Proper Operation