3.
Waitforthecompletionofthepairing(remainingsecondsis0).Ifpairingfails,anerrorisdisplayed.In
thiscase,repeatthepairingsteps.Iftheproblempersists,contactSolarEdgeSupport.Whenpairing
succeeds,thefollowingmessageisdisplayed:
P a i r i n g
P a i r i n g C o m p l e t e d
Thesystemstartupprocessbegins:
SincetheinverterisON,thepoweroptimizersstartproducingpowerandtheinverterstarts
convertingAC.
NOTE
When you turn ON the inverter ON/OFF switch, the DC cables carry a high voltage and the
power optimizers no longer output a safe 1V output.
Après avoir mis l'interrupteur ON/OFF de l'onduleur monophasé sur ON, les câbles DC portent
une haute tension et les optimiseurs de puissance ne génèrent plus la tension de sécurité de 1V.
WhentheinverterstartsconvertingpoweraftertheinitialconnectiontotheAC,theinverterenters
Standbymodeuntilitsworkingvoltageisreached.Thismodeisindicatedbytheflickeringgreen
inverterLED.
WhiletheinverterisinStandbymode,itmonitorsthegridandverifiescorrectgridvoltageand
frequency.Thefollowingmessageisdisplayed:
W a k i n g U p . . .
R e m a i n i n g : 0 5 1 S e c
ThecountdownindicatesthesecondsremaininguntilenteringtheProductionmode.Thistimeisin
accordancewithlocalregulationsandistypicallybetweenthreetofiveminutes.
Whencountdowniscomplete,theinverterentersProductionmodeandproducespower.The
steadilylitgreeninverterLEDindicatesthismode.
4.
ScrolltotheMaintenancemenuandselectOptimizer Conf.è Set Rapid ShutdownèEnable.
S e t R a p i d S h u t d o w n
E x i t