Energy Hub with Prism Technology Installation Guide

Table Of Contents
Figure 24: Connecting two Energy Hub inverters
3. On the second inverter, connect the cable to either the 2nd Inv RS485 connector or
the SMRT EV RS485 connector.
4. On both inverters, pass the 12V- RSD cable through Communication gland 2 and
connect it to the 2nd Inv-Battery connector.
5. Pull the cables lightly to make sure they are properly connected.
6. Close and tighten the communication glands.
To connect an additional HD-Wave inverter:
1. On the HD-Wave inverter, connect one end of the communication cable to the
RS485-1 connector on the communication board. For more information, refer to the
HD-Wave inverter Installation Guide
.
2. Pass the other end of the communication through Communication gland 2 of the
Energy Hub inverter.
3. Connect the cable to the 2nd Inv RS485 connector on the communication board.
4. Pull the cables lightly to make sure they are properly connected.
5. Close and tighten the communication glands.
Single Phase Energy Hub Inverter with Prism Technology MAN-01-00671-1.3
44 Connecting Multiple Inverters through RS485