Datasheet
MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US
ADDITIONAL FEATURES
Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional)
Revenue Grade Metering, ANSI
C12.20
Optional
(3)
Consumption metering
Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection
Rapid Shutdown - NEC 2014 and
2017 690.12
Automatic Rapid Shutdown upon AC Grid Disconnect
STANDARD COMPLIANCE
Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07
Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI)
Emissions FCC Part 15 Class B
INSTALLATION SPECIFICATIONS
AC Output Conduit Size / AWG
Range
1'' Maximum / 14-6 AWG 1'' Maximum /14-4 AWG
DC Input Conduit Size / # of Strings /
AWG Range
1'' Maximum / 1-2 rings / 14-6 AWG 1'' Maximum / 1-3 rings / 14-6 AWG
Dimensions with Safety Switch
(HxWxD)
17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185
in /
mm
Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg
Noise < 25 <50 dBA
Cooling Natural Convection
Operating Temperature Range -40 to +140 / -40 to +60
(4)
˚F / ˚C
Protection Rating NEMA 4X (Inverter with Safety Switch)
(3)
Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4 . For consumption metering, current transformers
should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box
(4)
Full power up to at lea 50˚C / 122˚F; for power de-rating information refer to: https://www.solaredge.com/sites/default/les/se-temperature-derating-note-na.pdf
Single Phase Inverter
with HD-Wave Technology for North America
SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/
SE7600H-US / SE10000H-US / SE11400H-US
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All
other trademarks mentioned herein are trademarks of their respective owners. Date: 01/2020/V01/ENG NAM. Subject to change without notice.
How to Enable Consumption Monitoring
By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their
household energy usage helping them to avoid high electricity bills