a. Lift the inverter from the sides, or hold it at the top and bottom of the inverter
to lift the unit into place. Do not lift holding the Safety Switch as it may be
damaged.
b. Lower the inverter onto the U-shaped indentations, as shown below. Let the
inverter lay flat against the wall or pole.
c.
Insert the two supplied screws through the outer heat sink fin on both sides of
the inverter and into the bracket.
Tighten the screws with a torque of 4.0 N*m / 2.9 lb.*ft.
Figure 17: Hanging the inverter on the brackets
6.
Optionally, secure the Safety Switch bracket to the wall/pole, using 3 screws:
NOTE
In case of inverter replacement with the Safety Switch still mounted, it is
recommended to use all 3 holes.
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.4
34 Mounting the Inverter