Installation Guide
Cellular
Thiswirelesscommunicationoption(purchasedseparately)enablesusingacellular
connectiontoconnectoneorseveraldevices(dependingonthedataplanused)tothe
monitoringplatform.
TheGSMPlug-inisprovidedwithausermanual,whichshouldbereviewedpriorto
connection.Refertohttps://www.solaredge.com/sites/default/files/cellular_gsm_
installation_guide.pdf
ZigBee
ThisoptionenableswirelessconnectionofoneorseveraldevicestoaZigBeeGateway,
forwirelesscommunicationtothemonitoringplatform.
TheZigBeeGatewayisprovidedwithaninstallationguide,whichshouldbereviewed
priortoconnection.Refertohttps://www.solaredge.com/sites/default/files/se-zigbee-
home-gateway-installation-guide.pdf.
Communication Connector
Acommunicationglandwithmultipleopeningsisusedforconnectionofthevariouscommunication
options.Thetablebelowdescribesthefunctionalityofeachglandopening.Unusedopeningsshould
remainsealed.
Opening for cable size (diameter) Connection type
2.5-5mm RS485
4.5-7mm,withcut Ethernet(CAT5/6)
2-4mm,withcut ZigBee,CDMAorGSMantennacable
Figure 21: Communication Gland
Chapter 6: Setting Up Communication
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00306-1.1
53