Installation Guide
M o d u l e : 1 0 2 8 8 0 6 3 1 B
E n e r g y [ W h ] : 5 6 . 7
V d c _ O [ V ] : 4 0 . 0
V d c _ I [ V ] : 3 8 . 3
I _ i n [ A ] : 7 . 8
T e m p [ C ] : 2 8 . 0
l Module:Poweroptimizerserialnumber
l Energy:poweroptimizerenergy
l Vdc_O:Poweroptimizeroutputvoltage
l Vdc_I:Poweroptimizerinputvoltage(modulevoltage)
l I_in:Poweroptimizerinputcurrent
l Temp:Poweroptimizertemperature
ID Status
Thisscreendisplaystheinvertersoftwareversionandthecountrytowhichtheinverterisconfigured.
D S P 1 / 2 : 1 . 0 2 1 0 / 1 . 0 0 3 4
C P U : 0 0 0 3 . 1 9 x x
C o u n t r y : U S A 1
l ID:TheinverterID.
l DSP 1/2:TheDSPdigitalcontrolboardfirmwareversion
l CPU:Thecommunicationboardfirmwareversion
l Country:thecurrentcountrysetting
Server Communication Status
S e r v e r : L A N < S _ O K >
S t a t u s : < O K >
x x x x x x x x
< E R R O R M E S S A G E >
NOTE
IftheconnectionmethodisCDMA(referredtoas"Cellular"inthestatusscreens)orGSM,theserver
screenisreplacedwiththeCellularorGSMstatusscreens(seeCellular Statusonpage49and
GSM Statusonpage49).
l Server:ThemethodofconnectiontotheSolarEdgemonitoringplatform.
l S_OK:TheconnectiontotheSolarEdgemonitoringplatformissuccessful(shouldappearonlyiftheis
connectedtotheserver).
l Status:DisplaysOKiftheinverterestablishedsuccessfulconnectionandcommunicationwiththe
specifiedserverport/(LAN,RS485orZigBeePlug-in).
l xxxxxxxx:Eight-bitEthernetcommunicationconnectionstatus:Astringof1sand0sisdisplayed.1
indicatesOK,0indicatesanerror.
l Error message,accordingtofailure.RefertoErrorCodesonpage63.
IP Status
ThisscreendescribestheEthernetconfiguration:IP,Mask,GatewayandMACaddress(MediaAccess
Control)oftheInverter.
Chapter 5: Configuring the Inverter
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00306-1.1
47