Installation Guide
WhiletheinverterisinWakeupmode,itmonitorsthegridandverifiescorrectgridvoltageandfrequency.
Thefollowingmessageisdisplayed:
W a k i n g U p . . .
R e m a i n i n g : 0 5 1 S e c
ThecountdownindicatesthesecondsremaininguntilenteringtheProductionmode.Thistimeisin
accordancewithlocalregulationsandistypicallybetweenthreetofiveminutes.
Whencountdowniscomplete,theinverterentersProductionmodeandproducespower.Thesteadily
litgreeninverterLEDindicatesthismode.
Step 3: Verifying Proper Activation
Afterthewake-uptimeisover,astatusscreensimilartothefollowingappearsontheinverterLCDpanel:
V a c [ V ] V d c [ V ] P a c [ W ]
2 4 0 . 7 3 7 1 . 9 2 3 4 9 . 3
P _ O K : X X X / Y Y Y < S _ O K >
. . . . . . . . . . . . . . . . . O N
1. Verifythefollowing:
l ThegreeninverterLEDissteadilylit.
l TheON/OFFindicatorontheLCDpanelreadsON.
l P_OK: XXX/YYY:Thereisaconnectiontothepoweroptimizersandatleastonepoweroptimizeris
sendingmonitoringdata.Optimizerssendtelemetriesinafrequencyofupto10minutes.
l S_OK appears,iftheinverterisconnectedtotheSolarEdgemonitoringplatform.
l Vac [V]specifiesthemeasuredgridACoutputvoltage.
l Vdc [v] specifiestheDCinputvoltage,whichshouldbeapproximatelytheinverterDCvoltage(model
dependent;refertotheinverterdatasheet)
l Pac [W]specifiestheACoutputpowerproduced.
2. Takenoteoftheserialnumberontheinverterlabelusingthedetachable2Dbarcodestickeroneach
device.ThisinformationisusedintheSolarEdgemonitoringplatformtoidentifythisinverter.
YourSolarEdgepowerharvestingsystemisnowoperational.
Reporting and Monitoring Installation Data
NOTE
Thissteprequiresconnectingoneofthecommunicationoptions.RefertoSetting Up
Communication onpage52.
The Monitoring System
Themonitoringplatformenablesaccessingsiteinformation,includingup-to-date
informationviewedinaphysicalorlogicalview.Themonitoringplatformisdescribedin
detailintheMonitoringPlatformUserGuide,availableontheSolarEdgewebsiteat
http://www.solaredge.us/files/pdfs/solaredge-monitoring-platform-user-guide.pdf.
Themonitoringplatformcandisplaylogicalandphysicallayoutsoftheinstalledsystem,
asfollows:
l Logical Layout:Showsaschematiclogicallayoutofthecomponentsinthesystem,suchas:inverters,
stringsandmodules,aswellastheirelectricalconnectivity.Thisviewenablesyoutoseewhich
modulesareconnectedineachstring,whichstringsareconnectedtoeachinverter,andsoon.
Chapter 5: Commissioning the Installation
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00306-1.1
35