Installation Guide

l Communication gland:Forconnectionofinvertercommunicationoptions.RefertoSettingUp
Communicationonpage52formoreinformation.
l Drain valve:Drainsanymoisturethatmaybeaccumulatedintheunit.
l LCD panel:Displaysinverterinformationandconfigurationparameters
l LCD LEDs:ThreeLEDslocatedtotherightoftheLCDindicatethefollowinginverterstatuses:
Color Description Functionality
Green Powerproduction
On-Theinverterisproducingpower.
Blinking-Standbymode.TheinverterisinStandbymodeuntilits
workingvoltageisreached.TheinverterthenentersProduction
modeandproducespower.
Off-Theinverterisnotproducingpower.ThismaybeduringNight
mode,whentheinverterON/OFFswitchisOFForwhenanerror
occurs.
Yellow
Communicationand
invertershutdown
Blinking:
o
Monitoringinformationisbeingreceivedfromapower
optimizer.
o
Theinverterisbeingshutdown.
Red Fault
On-Thereisanerror.RefertoErrors and Troubleshootingonpage
62formoreinformation.
Blinking-Theinverterisbeingshutdown.
AllLEDsturnonwhiletheinverterisbeingconfigured.
Opening Conduit Drill Guides
Thisstepmaybeperformedbeforeoraftermountingtheinverter.
To open conduit drill guides:
1. MovetheDCSafetyUnitandtheinverterON/OFFswitchtoOFF.
NOTE
WhentheSafetySwitchisOFF(forexampleduringmaintenance)itmaybelockedtopreventsafety
hazard:
1.MovethesafetyswitchtotheLockposition.
2.Insertthelockthroughtheknobopeningandlock.
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00306-1.1
24
Opening Conduit Drill Guides