Creating an Ethernet (LAN) Connection
This communication option enables using an Ethernet connection to connect the
inverter to the monitoring platform through a LAN.
Ethernet cable specifications:
Cable typea shielded Ethernet cable (Cat5/5E STP) may be used
Maximum distance between the inverter and the router100 m/ 330 ft.
NOTE
If using a cable longer than 10 m / 33 ft in areas where there is a
risk of induced voltage surges by lightning, it is recommend to
use external surge protection devices. For details refer to: