Installation Guide
Site status:
Production: The AC output power
Limit: Limitation setting (Export or Production)
Inverters: Number of connected inverters in the cluster, including the
master.
Inverter status: Displays status parameters of the primary unit of the
master
inverter. Refer to
Main Inverter Status
on page 59 for detailed information.
Inverter Units: Displays the status parameters of the
master’s
primary unit and
secondary units. Refer to the values description in the Main Inverter Status
section above.
Communication Status
This screen displays the status of connection option(s): LAN, RS485, cellular or ZigBee
Plug-in.
Communication
LAN
Connected
RS485-1
SESlave
NC
RS485-2
Modbus
2 of 2
Cellular
N/A
ZigBee
NC
For each communication option, one of the following statuses is displayed:
Connected: The inverter established a successful connection and
communication with the specified server port
NC: Not Connected. Refer to
Troubleshooting Communication
on page 87
S_OK: The connection to the monitoring platform is successful (should appear
only if the inverter is connected to the server)
N/A : Not Applicable
x of y: Number of devices connected out of all devices
Three Phase Inverter with Synergy Technology Installation MAN-01-00401-1.5
62 Viewing System Status