Figure 28: DC Spring-clamp terminals
5. Close the Connection Unit cover: Attach the switch cover and secure it by
tightening the six screws with a torque of 1.2 N*m / 0.9 ft.*lb.
6. Ensure proper conduit sealing; inspect the entire conduit run and use standard
conduit sealants to avoid water penetration.
Setting the Inverter to Support 208V 3-wire Grid
SolarEdge inverters that support the 208V 3-wire grid are equipped with two fuse
holders and a fuse in each unit. The position of the fuse configures the AC grid
connection: 4-wire or 3-wire grid connection. By default, the fuse is located in the 4-
wire fuse holder of the inverter, and in the 3-wire fuse holder there is a plastic dummy
fuse.
To set the inverter for 3-wire grid connection, you must move the fuse from the 4-wire
fuse holder, marked as Y GRID, to the 3-wire fuse holder, marked as GRID (see
Figure
29
).
To set the inverter for 208V 3-wire grid connection:
NOTE
Perform this procedure for all inverter units.
NOTE
Perform this procedure before connecting the inverterto the AC grid.
1.
Identify the fuse locations and the markings as described in
Figure 29
.
Figure 29: Fuse locations and markings
Chapter 4: Connecting the AC and Strings to the Connection Unit 49
Three Phase Inverter with Synergy Technology Installation MAN-01-00401-1.5