Install Manual

Table Of Contents
SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US UNITS
Utility Monitoring, Islanding Protection, Country
Configurable Thresholds
Yes
Charge Battery from AC (if Allowed) Yes
Typical Nighttime Power Consumption <2.5 W
OUTPUT - AC BACKUP
(1)
Rated AC Power in Backup Operation 2400 3050 4000 4800 6100 W
Peak AC Power (<10 sec) in Backup Operation 2700 3400 4500 5400 6900 W
AC L-L Output Voltage Range in Backup 211-264 Vac
AC L-N Output Voltage Range in Backup 105-132 Vac
AC Frequency Range in Backup (min - nom -
max)
55 - 60 - 65 Hz
Maximum Continuous Output Current in Backup
Operation
10 12.7 16.6 20 25.5 A
Peak AC Current (<10sec) in Backup Operation 11.25 14.2 18.75 22.5 30 A
GFDI 1 A
THD <5 %
OUTPUT - SMART EV CHARGER AC
Rated AC Power 9,600 W
AC Output Voltage Range 211-264 Vac
(1)
Not designed for standalone applications and requires AC for commissioning.
SolarEdge-Single Phase Energy Hub Inverter with Prism Technology MAN-01-00671-1.2