Datasheet

SE3000H-US SE3800H-US SE6000H-US SE7600H-US UNITS
OUTPUT
-
AC ON GRID
Rated AC Power 3000 3800 6000 7600 W
Maximum AC Power Output 3000 3800 6000 7600 W
AC Output Voltage Range 211-264 Vac
AC Frequency Range (min - nom - max) 59.3 - 60 - 60.5
(2)
Hz
Maximum Continuous Output Current 12.5 16 25 32 A
GFDI Threshold 1 A
Total Harmonic Di󰎯ortion (THD) <3 %
Power Factor 1, adju󰎯able -0.85 to 0.85
Utility Monitoring, Islanding Protection, Country Congurable Thresholds Ye s
Charge Battery from AC (if allowed) Ye s
Typical Nighttime Power Consumption <2.5 W
OUTPUT
-
AC BACKUP
(
3
)
Rated AC Power in Backup Operation
(4)
3000
3800
6000 7600 W
7600
*
AC L-L Output Voltage Range in Backup 211 - 264 Vac
AC L-N Output Voltage Range in Backup 105 - 132 Vac
AC Frequency Range in Backup (min - nom - max) 55 - 60 - 65 Hz
Maximum Continuous Output Current in Backup Operation 12.5
16
25 32 A
32
*
GFDI 1 A
THD <5 %
OUTPUT
-
SMART EV CHARGER AC
Rated AC Power 9600 W
AC Output Voltage Range 211
-
264 Vac
AC Frequency Range (min - nom - max) 59.3
-
60
-
60.5 Hz
Maximum Continuous Output Current @240V (grid, PV and battery) 40 Aac
INPUT
-
DC
(
PV AND BATTERY
)
Transformer-less, Ungrounded Ye s
Max Input Voltage 480 Vdc
Nom DC Input Voltage 380 Vdc
Reverse-Polarity Protection Ye s
Ground-Fault Isolation Detection 600kΩ Sensitivity
INPUT
-
DC
(
PV
)
Maximum DC Power 6000
7600
12000 15200 W
15200
*
Maximum Input Current
(5)
8.5
10.5
16.5 20 Adc
20
*
Max. Input Short Circuit Current 45 Adc
Maximum Inverter Eciency 99.2 %
CEC Weighted Eciency 99 %
2-pole Disconnection Ye s
INPUT
-
DC
(
BATTERY
)
Supported Battery Types LG Chem RESU 10H & RESU16H Prime
(6)
Number of Batteries per Inverter 1 or 2
(7)
Maximum Battery Capacity per Inverter 19.6 kWh
Continuous Power Per Inverter
(8)
5000 W
Peak Power
(8)
7000 W
Max Input Current @240V 18 Adc
2-pole Disconnection Ye s
SE3000H-US / SE3800H-US / SE6000H-US / SE7600H-US
(1)
Single Phase Energy Hub Inverter
with Prism Technology
for North America