HD Wave EV Charging Inverter Brochure

EV Charging Single Phase Inverter
for North America SE3800H-US / SE5000H-US/ SE6000H-US / SE7600H-US
© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered
trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners.
Date: 07/2018/V01/ENG NAM. Subject to change without notice.
INVERTER SPECIFICATIONS:
SE3800H-US SE5000H-US SE6000H-US SE7600H-US
OUTPUT
Rated AC Power Output
3800 @ 240V
3300 @ 208V
5000
6000 @ 240V
5000 @ 208V
7600 VA
Max. AC Power Output
3800 @ 240V
3300 @ 208V
5000
6000 @ 240V
5000 @ 208V
7600 VA
AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) 3 - 3 - Vac
AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 Vac
AC Frequency (Nominal) 59.3 - 60 - 60.5
(1)
Hz
Maximum Connuous Output Current 208V 16 - 24 - A
Maximum Connuous Output Current @240V 16 21 25 32 A
GFDI Threshold 1 A
Ulity Monitoring, Islanding Protecon, Country
C o n gu rab le Th re s h o l d s
Yes
INPUT
Maximum DC Power @240V 5900 7750 9300 11800 W
Maximum DC Power @208V 5100 - 7750 -
Transformer-less, Ungrounded Yes
Maximum Input Voltage 480 Vdc
Nominal DC Input Voltage 380
400
Vdc
Maximum Input Current 208V 9 - 13.5 -
Maximum Input Current @240V 10.5 13.5 16.5 20 Adc
Max. Input Short Circuit Current 45 Adc
Reverse-Polarity Protecon Yes
Ground-Fault Isolaon Detecon 600k Sensivity
Maximum Inverter Eciency 99.2 %
CEC Weighted Eciency 99 %
Nighme Power Consumpon < 2.5 W
ADDITIONALFEATURES
Supported Communicaon Interfaces RS485, Ethernet, ZigBee (oponal), Cellular (oponal)
Revenue Grade Data, ANSI C12.20 Oponal
(2)
Rapid Shutdown - NEC 2014 and 2017 690.12 Automac Rapid Shutdown upon AC Grid Disconnect
STANDARD COMPLIANCE
Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07
Grid Connecon Standards IEEE1547, Rule 21, Rule 14 (HI)
Emissions FCC Part 15 Class B
INSTALLATION SPECIFICATIONS
AC Output Conduit Size / AWG Range 3/4” minimum / 20-4 AWG
DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG
Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 in / mm
Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 lb / kg
Noise < 25 <50 dBA
Cooling Natural Convecon
Operang Temperature Range -13 to +140 / -25 to +60
(3)
(-40˚F / -40˚C opon)
(4)
˚F / ˚C
Protecon Rang NEMA 3R (Inverter with Safety Switch)
(1)
For other regional sengs please contact SolarEdge support
(2)
Revenue grade inverter P/N: SExxxxH-US000NNC2
OUTPUT—AC
Charging Level
AC Level 2
Connecon to the SolarEdge monitoring plaorm is required for rst EV charging
Rated AC Power Output (grid & PV) 9600 W
Nominal AC Output Voltage 240 Vac
Nominal AC Frequency 60 Hz
Maximum Connuous Output Current @240V (grid & PV) 40 Aac
Ground Fault Detecon Threshold 5 mA
ADDITIONALFEATURES
EV Charger Status LEDs, Fault Indicator Yes
EV Charger Unplugging Detecon Yes, current terminaon according to SAE J1772
EV Charger Ground Connecon Monitoring Yes, connuous
EV Charger Conguraon Via the monitoring app; Ethernet or ZigBee connecon is required
(5)
STANDARD COMPLIANCE
Safety
(6)
UL2594, UL2231-1, UL2231-2, NEC Arcle 625 compliant
EV Charger SAE J1772-2009
INSTALLATION SPECIFICATIONS
EV Charger Connector SAE J1772-2009
EV Charger Cable Length
(7)
25 / 7.6 (15 / 4.6 opon)  / m
EV Charger Cable Weight 12.5 / 5.7 (7.7 / 3.5 for 15 / 4.6m opon) lb / kg
EV Charger Cable Operang Temperature Range -22 to 122 / -30 to +50 ˚F / ˚C
Protecon Rang (connected to EV or with dust cap) NEMA 3R
EV CHARGER AND EV CHARGER CABLE SPECIFICATIONS:
(5)
Cellular connecon may be used; requires a SIM card with a 1GB data plan that should be purchased from a cellular provider
(6)
Pending cercaon
(7)
EV charger cable ordered separately
(3)
For power de-rang informaon refer to: hps://www.solaredge.com/sites/default/les/se-temperature-derang-note-na.pdf
(4)
-40 version P/N: SExxxxH-US000NNU4